General:
|
|
The 686-52 Read Write Module is a fully encapsulated device for reading and writing to a range of contactless read/write identification devices or TAGS operating at a frequency of 125kHz. Correctly formatted cards will have a unique 40 bit ID and a user data area capable of storing 100 bits of data without password protection, or 80 bits of data with password protection.
Since the 10-digit (HEX) ID Code is fully compatible with the EM H 4001/4002/4102 RFID Chip Family, the device can easily be integrated into existing access control or Time & Attendance Systems that are based on this chip family without having to change the existing card readers.
|
 |
Properties:
|
- Fully potted for improved weather resistance.
- Variable operating voltage - regulated 5V dc or unregulated 7 -12V dc.
- Read write tags supported: TEMIC e5551/4/5/7 series, Sokymat Q5, and equivalent devices.
- Control via full duplex RS232 (TTL levels) port at 19200 baud.
- Secure data encryption and decryption optional
- Support for password mode and answer-on-request.
- 1 open collector output for connecting a piezzo sounder (3.9 kHz)
- Data coding and decoding are completely handled within the 686-52 Module
|
Applications:
|
- Ticketing Systems
- Parking Systems
- Security Systems i.e. access control
- Ski lifts
- Combined Systems i.e. for leisure parks
- Membership cards for clubs
- Control of photocopiers or sunbeds by RFID debit or credit card
|
Technical Data:
|
|
• Frequency:
|
125 kHz
|
|
• Data Format:
|
64 bit Manchester Code
|
|
• Interface:
|
RS232 (TTL levels) port at 19200 baud.
|
|
• ID-Number:
|
10-digit in Hex -Wiegand-Code Format
|
|
• Dimensions:
|
46 x 30 x 11mm
|
|
• Weight:
|
< 30 grams
|
|
• Operating Temperature:
|
0 - +50°C
|
|
• Humidity:
|
10 - 90%, non-condensing
|
|
• Operating Voltage:
|
regulated 5V dc or unregulated 7 -12V dc. Current consumption is 75mA typical.
|
|
• Transponder Chip:
|
TEMIC e5551/4/5/7 series, Sokymat Q5, and equivalent devices.
Read-only: 10-digit ID-Code (HEX), compatible with EM H 4001/2, 4102 Format
Read AND Write: 4 or 5 blocks of 20bit in the Data Pages
Optional password and data encryption |
|
|
Data sheet
|
|